Speciale valvole industriali e manutenzione d’impianti


































                                                                                      Figure 2: Cryogenic top entry TOVs offer
                                                                                      an easily accessible trim that can be remo-
                                                                                      ved with the extended bonnet, making it
                                                                                      safer to repair.




                                  nents operating at temperatures down to -254   is safe to repair, there is no exposure of service
                                  °C (-425 °F).                            personnel to safety  risks  and there  is  also  the
                                  Whenever inline access is mandatory, differen-  possibility of addressing operability problems
                                  tly from a side entry TOV, the trim of a cryo-  linked to the bearing areas.
                                  genic Vanessa top entry buttweld TOV can be
                                  completely removed together with the extended
                                  bonnet from the body and every component can   For more information, please visit
                                  be repaired or replaced (fig. 2). Thus, the valve   www.emerson.com/vanessa








































                                                                                Impiantistica Italiana - Novembre-Dicembre 2017  73 73