Table 3 – Mechanical features of the variable frequency converter

Electrical (converter)                                             −       SVTN 10K8 W33 24P
Model                                                              −       VSI - NPC - PWM digital - IGBT
Type                                                               −       2 quadrants w/o braking
Operational Mode                                                           sensorless
Control type                                                       −       10800 kVA
Power                                                              %       98
Efficiency at rated power                                          −       24 pulse configuration diode rectifier
Front end AC/DC converter type                                     V/A     4 × 1800 / 1080
Input rated voltage / current / frequency                          −       3 phase
Input type                                                         Hz      50
Input frequency                                                    −       0.96
Line side power factor                                             V/A     3300 / 1666
Output rated voltage / current                                     −       3 phase
Output type                                                        Hz      5÷70
Output frequency range                                                     dV/dt reactor
Output filter

Mechanical (cabinet)                                               −       IP 31
Protection degree                                                  −       IP 20 (only for control cabinet)
Protection degree at open doors                                    −       indoor (inside LER)
Installation                                                               front
Accessibility                                                      −       bottom / bottom
Cable inlet / outlet                                               m       < 250
Motor feeding cable length                                         dB(A)   70
Noise level                                                        kg      6500
Mass                                                               −       deionized water in closed loop with internal water-to-water
Primary cooling circuit                                                    heat exchanger
                                                                   −       water (between VFD and chiller)
Secondary cooling circuit                                                  bottom
Water inlet / outlet flanges (VFD to chiller)

Reliability and availability                                       h       50000
MTBF (Medium Time Between Failures)                                min     30
MTTR (Medium Time To Repair)                                       months  6
MTBM (Medium Time Between Maintenance)

64 Impiantistica Italiana - Maggio-Giugno 2015